Sporlan distributor Type • CDS-16, CDST-17, CDST-2, CDST-4, CDST-7 , CDST-7, CDST-9, CDS-17, CDS-2, CDS-4, CDS-7, CDS-9 Application • Electric Evaporator Pressure Regulators Refrigerant Type • All common HCFC and HFC refrigerants including R-410A and subcritical R-744. Motor Type • 2 Phase Bipolar Wet Motor For Fluid Type • All common Mineral, Polyester, and Alkybenzene oils. Input Voltage • 12 Volt DC -5% +10% (measured at the valve leads) Inlet Connection Size • 1/2" to 2.1/8" (ODF) inch Outlet Connection Size • 1/2" to 2.1/8" (ODF) inch
หมวดหมู่ : PRODUCTS ,  VALVES (GENERAL) ,  SPORLAN , 
แบรนด์ : Sporlan distributor
Share
ผู้จำหน่าย Electric Regulator Valves แบรนด์ Sporlan (สปอร์แลน) CDS Series วาล์ว Parker Sporlan เป็นวาล์วไฟฟ้าที่ทำงานด้วยสเต็ปเปอร์มอเตอร์ สำหรับใช้ในระบบทำความเย็น และระบบปรับอากาศแบบขยายโดยตรง (air conditioning systems) การใช้งานได้แก่ Evap
ผลิตภัณฑ์อุตสาหกรรมวาล์ว Sporlan Electric Pressure Regulating Valves CDS Series CDS-16, CDST-17, CDST-2, CDST-4, CDST-7 , CDST-7, CDST-9, CDS-17, CDS-2, CDS-4, CDS-7, CDS-9 เป็นวาล์วสเต็ปมอเตอร์แบบควบคุม ออกแบบมาเพื่อให้มีส่วนน้อยที่สุด แรงดันตกสู่ระบบ นอกเหนือจากแบบดั้งเดิมแล้ว การประยุกต์ใช้เป็นตัวควบคุมความดันเครื่องระเหยไฟฟ้า วาล์ว CDSยังสามารถใช้เป็นการเรียกคืนความร้อน, แรงดันตัวรับ วาล์วควบคุมหรือดิฟเฟอเรนเชียลไลน์ลิควิด โดยการให้สัญญาณที่ซิงโครไนซ์กับสเต็ปมอเตอร์แบบแยกเชิงมุม วาล์ว CDS ได้รับการอนุมัติให้ใช้กับสารทำความเย็น HCFC, HFC, HFO และ HC และน้ำมันแร่ อัลคิลเบนซีน และโพลิโอเลสเตอร์ (Mineral, Alkylbenzene and Polyolester Oils.)
การเคลื่อนไหวถูกแปลผ่าน Digital Linear Actuator (DLA) ไปสู่ตำแหน่งเชิงเส้นตรงของลูกสูบวาล์ว ลูกสูบและพอร์ตที่สมดุลนั้นมีเอกลักษณ์เฉพาะตัว ให้ความละเอียดการไหลและประสิทธิภาพที่ยอดเยี่ยม การใช้งานและสภาวะการทำงานที่หลากหลาย วาล์ว CDS เชื่อมต่อกับตัวควบคุมที่ใช้ไมโครโปรเซสเซอร์ได้อย่างง่ายดาย รวมถึงคอนโทรลเลอร์ที่ให้มาด้วย Sporlan
และวาล์ว Sporlan CDS สามารถซ่อมบำรุงได้ จึงสามารถทำความสะอาดลูกสูบและพอร์ตได้ และเปลี่ยนชุดมอเตอร์หากจำเป็น นอกจากนี้ วาล์ว CDS ยังมีก๊อกแรงดันเสริมสำหรับการวัดความดันของระบบ หรือการอพยพออกจากระบบและชาร์จสารทำความเย็น
Technical Specifications
Model Number | Please Configure Part for Model Number |
Application | Electric Evaporator Pressure Regulators |
Refrigerant Type | All common HCFC and HFC refrigerants including R-410A and subcritical R-744. |
Motor Type | 2 Phase Bipolar Wet Motor |
For Fluid Type | All common Mineral, Polyester, and Alkybenzene oils. |
Input Voltage | 12 Volt DC -5% +10% (measured at the valve leads) |
Product Sporlan Type | CDS-16, CDST-17, CDST-2, CDST-4, CDST-7 , CDST-7, CDST-9, CDS-17, CDS-2, CDS-4, CDS-7, CDS-9 |
Inlet Connection Size | 1/2" to 2.1/8" (ODF) inch |
Outlet Connection Size | 1/2" to 2.1/8" (ODF) inch |
Maximum Operating Pressure | 46.9 or 48.3 bar |
Maximum Pressure Rating | 680 psi or 700 psi |
Cable Length | 3 m, 6.1 m, 12.2 m, 9.1 m, N/A m, 10', 20', 40', 30' ft |
Function | 2 way, 3 way, NA |
Configuration | Angle or Straight Through, 2 way |
Additional Options | Not Applicable, Pressure Tap |
Cable Type | Hermetic Cable with Stripped End or IP67 Removable |
Minimum Operating Temperature | -40°F, -50°F |
Actuation Type | Motor |
Seal Material | Synthetic, Synthetic seal |
Body Material | Brass |
Connection Size | 1/2" to 2.1/8" (ODF), 1.1/8" to 2.5/8" (ODF) |
Connection Type | ODF |
Flow Rate | NA |
Maximum Operating Temperature | 240°F, 155°F |
Maximum Pressure Setting | NA |
Mounting Type | NA |
ANSI Flange Class | NA |
Full Product Description
The Parker Sporlan's CDS family represents a line of electronically controlled step motor valves, designed to contribute minimal pressure drop to the system. In addition to their traditional application as Electric Evaporator Pressure Regulators, CDS valves can also be applied as Heat Reclaim, Head Pressure Control or Liquid Line Differential valves. By providing synchronized signals to the step motor, discrete angular movements are translated through a Digital Linear Actuator (DLA) into precise linear positioning of the valve piston. The balanced pistons and ports are uniquely characterized, providing superb flow resolution and performance across a range of applications and operating conditions. The CDS valves interface easily with microprocessor based controllers, including Sporlan supplied controllers.
FEATURES AND BENEFITS
• Step motor operated for precise control
• High resolution drive assembly
• Solenoid tight seating
• Corrosion resistant materials used throughout
• Field proven reliability
• Low power consumption (4 watts or less)
• Balanced port designs
• Compatible with most HCFC and HFC refrigerants
and oils, in addition to subcritical CO2
• Self lubricating materials used for long life
• High linear force output
THE VALVES
Sporlan CDS valves are available in two styles - the CDS-2, CDS-4 and CDS-7 provide 2500 steps of resolution, while the larger CDS-9, CDS-16 and CDS-17 provide 6386 steps of resolution. 12 VDC step motors coupled to an integral gear reduction system give the valves unparalleled accuracy and repeatability over the entire operating range. Capable of tremendous versatility, CDS valves can be used to replace a variety of mechanical and solenoid valves throughout typical refrigeration and air conditioning systems, where low pressure drop and precise refrigerant flow control are desired. And because the valves are powered by an external controller, no pilot lines or high to low side bleeds are required. The tables found at the back of this bulletin show actual capacity at specific conditions representative of several typical applications.
CDS valves have years of proven field performance, but also offer excellent serviceability. A simple cartridge design permits all moving parts to be replaced as a unit, leaving the valve body in the line. The CDS-2, CDS-4 and CDS-7 also offer a removable cable, which reduces damage potential during brazing, and eliminates rewiring when servicing the motor cartridge. Caution: The CDS-9, CDS-16 and CDS-17 feature a hermetic cable, and no attempt should be made to remove the cable.
VALVE OPERATION
The CDS valves are driven by the electronically controlled rotation of a step motor. The step motor drives a gear train and lead screw to position a piston, modulating flow through the port. The two-phase motor is driven in bipolar mode. Two discrete sets of motor windings are powered in sequence to rotate the rotor 3.6 degrees per step. Polarity of the drive signal reverses for each step. The sequencing is accomplished electronically through a bipolar drive circuit, an example of which is shown in Figure 1. Further exploration of this drive circuit and alternatives is beyond the scope of this bulletin.
Markets
• Food Retail & Food Service Refrigeration
• Commercial Air Conditioning & Chillers
• Environmental Chambers & Specialty Applications
Applications
• Electric Evaporator Pressure Regulator
• Receiver Pressurization
• Condenser Holdback
Compatible with Sporlan Controllers—Kelvin II Series and Interface Boards. Also compatible with many third party controllers. For more information, refer to "Product Support" tab for more information on electronic controllers.
ติดต่อขอใบเสนอราคา ช่องทางโทรศัพท์ และ ไลน์
- คุณจุฑามาศ (กุ๊กไก่) : 02-943-4814
E-mail : pneutecthai@gmail.com
Line : @pneutecthai
Literature and Reference Materials
CDS ELECTRIC PRESSURE REGULATING VALVES.PDF
Bulletin 100-40 - Sporlan CDS Electric Evaporator Control Valves.PDF
Bulletin 100-40-1 - Sporlan (S)ORIT to CDS Conversion Kits.PDF
Bulletin 100-40-2 - Sporlan A8/Sport to CDS Conversion Kits.PDF
Bulletin 100-50-5 - Sporlan Kelvin II Series Electric Valve Controllers.PDF
Bulletin 100-50-5.5 - Sporlan Pressure Control - Installation and Operation Instructions.PDF
Form 100-419 - Sporlan Electric Valve Poster.PDF
SD-218 - Sporlan Step Motor Evaporator Control Valves Installation Instructions.PDF
SD-297 - Sporlan (S)ORIT to CDS Conversion Kit Installation Instructions.PDF
SD-399 - Sporlan A8/Sport to CDS Conversion Kits Installation Instructions.PDF